KTH’s high water table was causing their floors to delaminate whenever there was a lot of rain. We removed the laminated coatings and polished their concrete so that the hydrostatic water pressure wouldn’t affect the floor anymore.

The Problem

KTH’s facility was built on an area of land that was susceptible to a high water table. So whenever the area received a lot of rain, the water would cause hydrostatic pressure, forcing any coatings that were on the floors to delaminate.

The Solution

Polished concrete was installed at the facility. Creating an easy to maintain surface and eliminating the coating failures that occurred in the past.

The Process

Remove the existing coatings and polish the concrete. Polished concrete is not affected by the hydrostatic water pressure and has no finish to delaminate.